青青草国产精品一区二区,日本苍井空精品啪啪,亚洲一区二区视频,日产在线精品一区二区三区,精品国产乱码久久久蜜桃动漫,米奇色888狠狠俺去啦,黄色视频免费直接看,天天插天天射天天噜

AC5000L-81 series chilled water column precision air conditioner

AC5000L-81 series chilled water row precision air conditioner is a cooling, efficient and energy-saving precision air conditioner for computer rooms, which is suitable for micro-module data centers with high temperature or humidity control precision and high sensible heat requirements. The chilled water inter-row air conditioner is placed in the rack and installed side by side with the server cabinet. The air is discharged from the front of the unit, and the air is returned from the rear. The air is cooled near the heat source, and the cooling efficiency is high.

consult

馬政發(fā)13911282237

  • Safe and reliable

    Green, safe and reliable; The use of chilled water as a refrigerant is the closest to the natural air conditioning method, green, healthy, environmental protection; High performance EC centrifugal fan, large air volume, high static pressure, smooth operation, low noise; Perfect automatic alarm and diagnosis function, all-round protection of air conditioning units, but also more effective to prevent failure, extend the service life of air conditioning units.

  • Energy efficient

    Large flow coefficient of proportional integration electric two-way valve, real-time regulation system water flow; Refrigeration near the heat source, short airflow path, small cold loss; Maximize the use of the space inside the unit to improve the heat exchange area, better heat exchange effect, higher machine performance; The unit uses copper tube hydrophilic aluminum fin heat exchanger, which has high heat density and higher heat exchange efficiency.

  • Intelligent control

    Intelligent controller for PID operation, automatic adjustment of water saving valve opening and fan speed; The control mode can be freely selected for return air temperature control or supply air temperature control; The standard RS485 communication interface can realize coordination and linkage with external devices to help the entire room air conditioning system intelligent and energy-saving control.

Application scenario

  • Data Center
    Such as supercomputing center, data center, cloud computing center, communication room, switching room, transmission room, electronic information system room

  • Integrated Micromodule Data Center

  • Precision environments such as container data centers
The air conditioner in a small equipment room is suitable for places that have high requirements on ambient temperature and humidity.
Data centers with high heat density and low PUE values, computer rooms. Such as supercomputing center, data center, cloud computing center, communication room, switching room, transmission room, electronic information system room integrated micro-module data center. Precision environments such as container data centers.
    Technical specification
    Model AC5000L-81 series
    Function Optional constant temperature and humidity function
    Return-air condition 37℃/24%
    Main Power supply 380V/3p/50Hz
    Chilled water inlet and outlet temperature (℃) 15/21 12/18 10/15 7/12
    Total cooling capacity (kw) 60.5 65.0 73.0 86.1
    Net cooling capacity (kw) 60.5 65.0 73.0 81.2
    Water flow (m³ /h) 10.3 9.3 12.5 14.7
    Heating capacity (kW) 6.0
    Humidification capacity (kg/h) 3.0
    Water resistance (kPa) 75.0 78.5 79.0 80.0
    Circulating Air Volume (CMH) 12000
    Number of fans 3
    Size: Width * Depth * Height (mm) 600*1200*2200